Product View: 86(s)

Main Products:

inverter

Get Quotations
Home > Product > Inverter> Sungrow SG33KTL-M
Sungrow SG33KTL-M
Sungrow SG33KTL-M
Product Description
 
  SG33KTL-M
High Yield Easy O&M
Max. efficiency 98.5 %,European efficiency 98.3 %
Long-time overload at 1.1 Pn (SG33KTL-M)
Full power operation without derating at 50 
Up to 3 MPP trackers
Integrated string current monitoring function for
fast trouble shooting
Compact design and light weight for easy installation
Plug-in design of fan and SPD, easy for on-site
maintenance
   
Saved Investment Grid Support
Max. DC/AC ratio up to 1.4
Can be installed horizontally, saving installation cost
Integrated DC combiner box and DC/AC
overvoltage protection
Compliance with standards: CE, IEC 62109,
IEC 61727, IEC 62116, VDE 0126-1-1, VDEAR-
N-4105
Low/High voltage ride through (L/HVRT)
Active & reactive power control and power
ramp rate control
   
Input (DC)  
Max. PV input voltage 1100 V
Min. PV input voltage / Startup input voltage 200 V / 250 V
Nominal input voltage 585 V
MPP voltage range 200  1000 V
MPP voltage range for nominal power 500  850 V
No. of independent MPP inputs 3
Max. number of PV strings per MPPT 2003-3-2
Max. PV input current 88 A (33 A / 33 A / 22 A)
Max. current for input connector 12 A
Max. DC short-circuit current 96 A (36 A / 36 A / 24 A)
   
Output (AC)  
AC output power 36000 VA @ 45  / 33000 VA @ 50 
Max. AC output current 53.5 A
Nominal AC voltage 3 / PE or 3 / N / PE, 230 / 400 V
AC voltage range 310  480 V
Nominal grid frequency / Grid frequency range 50 Hz / 45  55 Hz, 60 Hz / 55  65 Hz
THD < 3 % (at nominal power)
DC current injection < 0.5 % In
Power factor at nominal power / Adjustable power factor > 0.99 / 0.8 leading  0.8 lagging
Feed-in phases / Connection phases 3-3
   
Efficiency  
Max. efficiency / Euro. efficiency 98.5 % / 98.3 %
   
General Data  
Dimensions (W*H*D) 525*740*240 mm
Weight 48 kg
Isolation method Transformerless
Degree of protection IP65
Night power consumption < 2 W
Operating ambient temperature range -25 to 60  (> 50  derating)
Allowable relative humidity range (non-condensing) 0  100 %
Cooling method Smart forced air cooling
Max. operating altitude 4000 m (> 3000 m derating)
Display / Communication Graphic LCD / RS485
DC connection type MC4 (Max. 6 mm² )
AC connection type Screw clamp terminal (Max. 50 mm² )
Compliance IEC 62109, IEC 61727, IEC 62116, IEC 60068,
  IEC 61683, CE, IEC 61000-3-11/-12, VDE 0126-1-1,
  VDE-AR-N-4105, CEA
Grid support LVRT, HVRT, active & reactive power control and
  power ramp rate control
Type designation SG33KTL-M-10